電(dian)機(jī)、傳(chuan)動(dòng)裝(zhuang)置、泵、壓縮機(jī)
瞬态與電(dian)壓不平衡
最常影響工(gong)業工(gong)廠(chǎng)的(de)電(dian)功率問題包括電(dian)壓暫降咊(he)暫升、諧波(bo)、瞬态,以(yi)及(ji)電(dian)壓咊(he)電(dian)流不平衡。
Top causes of single-phase motor malfunctions
Most problems with single-phase motors involve the centrifugal switch, thermal switch, or capacitor(s). If the problem is in the centrifugal switch, thermal switch, or capacitor, the motor is usually serviced and repaired. However, if the motor is more than 10 years old and less than 1 HP, the motor is usually replaced. If the motor is less than 1/8 HP, it is almost always replaced.
13 common causes of motor failure
This article demonstrates how to detect the 13 most common causes of winding insulation and bearing failure in advance.
How to measure output voltage from a VFD to a motor
How to measure output voltage from a VFD to a motor